Call Toll Free 1800 102 00 55 OR Email info@iplgroup.com
Model : SRK 13 YXP – W6
- Hi- Wall Mounted, Hyper Inverter
- Eco Smart Hyper Inverter AC
- Refrigerant : R32
- Cooling Only
- Model : SRK 13 YXP – W6
- Ton : 1.0
Call Toll Free 1800 102 00 55 OR Email info@iplgroup.com
ECO SMART HYPER INVERTER AIR CONDITIONER gives 1.5 Times bigger area coverage compared to Conventional AC & still gives Electricity Saving Upto 47%*.
ECO SMART - HEAVY DUTY AC ( R410A ) | |||||
MODEL | Unit | SRK05CR-S | SRK10CRS-S6 | SRK13CRS-S6 | |
Indoor Unit | SRK05CR-S | SRK10CRS-S6 | SRK13CRS-S6 | ||
Outdoor Unit | SRC20CSS-S6/A | SRC21CNS-S6 | SRC25CSS-S6/A | ||
Tonnage | Ton | 1.7 | 1.5 | 2.2 | |
BEE - Star Rating -2019 | 3 Star | 3 Star | 3 Star | ||
Refrigerant Control & Expansion | Dual Capillary Expansion | ||||
Fixed Speed Compressor Type | Super Tropical - Return Cooled Rotary | ||||
Power Source | 1 Phase, 230 V, 50 Hz | ||||
Maximum Cooling Capacity* | BTU/hr | 5998 | 10499 | 13501 | |
Rated Cooling Capacity at | 100% Load | 5000 | 9212 | 12283 | |
Rated Cooling Capacity at | 50% Load | Not Applicable for Fixed Speed AC | |||
Maximum Cooling Capacity* | Watts | 1758 | 3077 | 3957 | |
Rated Cooling Capacity at | 100% Load | 1465 | 2700 | 3600 | |
Rated Cooling Capacity at | 50% Load | Not Applicable for Fixed Speed AC | |||
Rated Power Consumption at | 100% Load | watts | 375 | 740 | 1000 |
Rated Power Consumption at | 50% Load | Not Applicable for Fixed Speed AC | |||
Rated EER / COP at | 100% Load | W/w | 3.91 | 3.65 | 3.60 |
Rated EER / COP at | 50% Load | Not Applicable for Fixed Speed AC | |||
BEE Rated Indian Seasonal Energy Efficiency Ratio | ISEER | Not applicable | 3.65 | 3.60 | |
Input Power ** ( Minimum ~ Maximum) | Watts | 300 ~ 375 | 550 ~ 740 | 700 ~ 1000 | |
Current ( minimum ~ maximum ) ** | A | 1.5 ~ 1.8 | 3.0 ~ 3.3 | 4.0 ~ 4.7 | |
Dimension (H x W x D) | Indoor Unit | mm | 262 x 615 x 210 | 268 x 790 x 213 | |
Outdoor Unit | mm | 435x645(+50)x275 | 540 x 780 x 290 | 595 x 780 x 290 | |
Weight | Indoor Unit | Kgs | 6 | 9.5 | 9.5 |
Outdoor Unit | Kgs | 20 | 30 | 34 | |
Air Flow ( CMH ) | Indoor Unit | m3/hr | 510 | 650 | 750 |
Long Reach AirFlow Upto | Indoor Unit | Meter | 2.43 | 4.57 | 6.09 |
Sound Level (H/M/L) | Indoor Unit | dB | 38 / 34 / 26 | 38 / 34 / 31 | 38 / 34 / 31 |
Louver Swing | Indoor Unit | 2D | 3D + 3D AUTO | 3D + 3D AUTO | |
Special Filter | Indoor Unit | Anti - Bacterial | Enzyme + Solar + Anti - Bacterial Filter | ||
Blower Fan | Indoor Unit | Anti - Micro Bial | |||
DC Fan Motor Speed | Indoor Unit | Auto / Powerful / High / Med / Low / Dry | |||
Refrigerant Injection in Coil | Indoor Unit | 2 Point - Multi Port | 4 Point - Multi Port | 4 Point - Multi Port | |
Refrigerant Piping | Liquid Line | mm | 6.35 ( 1/4" ) | 6.35 ( 1/4" ) | 6.35 ( 1/4" ) |
Gas Line | mm | 9.52 ( 3/8" ) | 9.52 ( 3/8" ) | 12.7 ( 1/2" ) | |
Main Power Supply to | Indoor Unit | 2.5 mm2 x 3 cores (earthing cable ) | |||
Connecting wiring between | B/w IDU & | 2.5 mm2 x 4 cores (earthing cable ) | |||