ECO SMART – HYPER INVERTER – AC

Model : SRK 13 YXP – W6

  • Hi- Wall Mounted, Hyper Inverter
  • Eco Smart Hyper Inverter AC
  • Refrigerant : R32
  • Cooling Only
  • Model : SRK 13 YXP – W6
  • Ton : 1.0
SSRK 05 CRS
SRK 10 CRS-S6

Model : SRK 18 YXP – W6

  • Hi- Wall Mounted, Hyper Inverter
  • Eco Smart Hyper Inverter AC
  • Refrigerant : R32
  • Cooling Only
  • Model : SRK 18 YXP – W6
  • Ton : 1.5

Model : SRK 24 YVS – W6 Ton :2.2

  • Hi- Wall Mounted, Hyper Inverter
  • Eco Smart Hyper Inverter AC
  • Refrigerant : R32
  • Cooling Only
  • Model : SRK 24 YVS – W6
  • Ton : 2.2
SRK 12 CR-S6

ECO SMART HYPER INVERTER AIR CONDITIONER gives 1.5 Times bigger area coverage compared to Conventional AC & still gives Electricity Saving Upto 47%*.

ECO SMART HEAVY DUTY AIRCONDITIONER
Presenting India's Highest Energy Saving 1.1 Ton Eco Smart Heavy Duty AC With R410A Refrierant & With Maximum 3.96*EER.
Comfortable Air Flow Function
Clean Air
Maintenance
Comfortable Function
Other
Convenient & Economy Functions
<!-- table td{ border: 1px solid#000; height: 40px; text-align:center;padding:5px; width: 650px; }
ECO SMART - HEAVY DUTY AC ( R410A )
MODEL Unit SRK05CR-S SRK10CRS-S6 SRK13CRS-S6
Indoor Unit SRK05CR-S SRK10CRS-S6 SRK13CRS-S6
Outdoor Unit SRC20CSS-S6/A SRC21CNS-S6 SRC25CSS-S6/A
Tonnage Ton 1.7 1.5 2.2
BEE - Star Rating -2019 3 Star 3 Star 3 Star
Refrigerant Control & Expansion Dual Capillary Expansion
Fixed Speed Compressor Type Super Tropical - Return Cooled Rotary
Power Source 1 Phase, 230 V, 50 Hz
Maximum Cooling Capacity* BTU/hr 5998 10499 13501
Rated Cooling Capacity at 100% Load 5000 9212 12283
Rated Cooling Capacity at 50% Load Not Applicable for Fixed Speed AC
Maximum Cooling Capacity* Watts 1758 3077 3957
Rated Cooling Capacity at 100% Load 1465 2700 3600
Rated Cooling Capacity at 50% Load Not Applicable for Fixed Speed AC
Rated Power Consumption at 100% Load watts 375 740 1000
Rated Power Consumption at 50% Load Not Applicable for Fixed Speed AC
Rated EER / COP at 100% Load W/w 3.91 3.65 3.60
Rated EER / COP at 50% Load Not Applicable for Fixed Speed AC
BEE Rated Indian Seasonal Energy Efficiency Ratio ISEER Not applicable 3.65 3.60
Input Power ** ( Minimum ~ Maximum) Watts 300 ~ 375 550 ~ 740 700 ~ 1000
Current ( minimum ~ maximum ) ** A 1.5 ~ 1.8 3.0 ~ 3.3 4.0 ~ 4.7
Dimension (H x W x D) Indoor Unit mm 262 x 615 x 210 268 x 790 x 213
Outdoor Unit mm 435x645(+50)x275 540 x 780 x 290 595 x 780 x 290
Weight Indoor Unit Kgs 6 9.5 9.5
Outdoor Unit Kgs 20 30 34
Air Flow ( CMH ) Indoor Unit m3/hr 510 650 750
Long Reach AirFlow Upto Indoor Unit Meter 2.43 4.57 6.09
Sound Level (H/M/L) Indoor Unit dB 38 / 34 / 26 38 / 34 / 31 38 / 34 / 31
Louver Swing Indoor Unit 2D 3D + 3D AUTO 3D + 3D AUTO
Special Filter Indoor Unit Anti - Bacterial Enzyme + Solar + Anti - Bacterial Filter
Blower Fan Indoor Unit Anti - Micro Bial
DC Fan Motor Speed Indoor Unit Auto / Powerful / High / Med / Low / Dry
Refrigerant Injection in Coil Indoor Unit 2 Point - Multi Port 4 Point - Multi Port 4 Point - Multi Port
Refrigerant Piping Liquid Line mm 6.35 ( 1/4" ) 6.35 ( 1/4" ) 6.35 ( 1/4" )
Gas Line mm 9.52 ( 3/8" ) 9.52 ( 3/8" ) 12.7 ( 1/2" )
Main Power Supply to Indoor Unit 2.5 mm2 x 3 cores (earthing cable )
Connecting wiring between B/w IDU & 2.5 mm2 x 4 cores (earthing cable )
Area Coverage *** Sq. Meter 4.64 ~ 6.96 9.29 ~ 13.00 11.98 ~ 15.97
--> <!-- Click here to Download Specification -->