SPECIFICATIONS | ECO SMART - DUCT CONNECTED MEDIUM STATIC - FDUM SERIES (R410A) |
|||||
Unit | FDUM50CR-S |
FDUM71CR-S |
FDUM100CR-S |
FDUM125CR-S |
||
Model | Indoor Unit |
FDUM50CR-S |
FDUM71CR-S |
FDUM100CR-S |
FDUM125CR-S |
|
Outdoor Unit |
FDC50CR-S |
FDC71CR-S |
FDC100CR-S |
FDC125CR-S |
||
Super Tropical - return Cooled Compressor | Rotary |
Scroll |
||||
Type of AC | Heavy duty AC |
Hybrid AC |
||||
Power Source | 1 Phase, 220 ~ 240 V, 50 Hz |
3 Phase, 380 ~ 440 V, 50Hz |
||||
Maximum Cooling Capacity* |
Ton |
1.5 |
2.2 |
3.0 |
4.0 |
|
Watts |
5363 |
7620 |
10550 |
14068 |
||
BTU/h |
18300 |
26000 |
36000 |
48000 |
||
Maximum EER / COP* | W / w |
3.57 |
3.54 |
3.51 |
3.51 |
|
Rated Cooling Capacity |
Ton |
1.5 |
2.0 |
3.0 |
4.0 |
|
Watts |
5000 |
7108 |
10000 |
12500 |
||
BTU/h |
17060 |
24255 |
34120 |
42650 |
||
Input Power** (Minimum ~ Maximum) | Watts |
1300 ~ 1500 |
1900 ~ 2150 |
2700 ~ 3000 |
3700 ~ 4000 |
|
Rated EEr / COP | W / w |
3.33 |
3.30 |
3.33 |
3.12 |
|
Air Flow | Indoor Unit |
CMH |
800 |
1200 |
1950 |
2200 |
Long reach AirFlow Upto | Indoor Unit |
Feet |
8 |
12 |
20 |
20 |
Sound level (H/M/l0 | Indoor Unit |
dB |
37 / 32 / 29 / 26 |
38 / 33 / 29 / 25 |
44 / 38 / 36 / 30 |
45 / 40 / 34 / 29 |
Louver Swing | Indoor Unit |
Not Applicable |
||||
Remote Control | Indoor Unit |
Standard - Wired Controller include / Wireless Remote Controller Optional |
||||
Self Diagnosis Function | Indoor Unit |
Yes |
||||
Filter | Indoor Unit |
Anti - Bacterial - Optional Filter Kit On Demand chargeble |
||||
Fan | Indoor Unit |
Centrifugal Blowerr |
||||
DC Fan Motor Speed | Indoor Unit |
Auto / High / Medium / Low / Dry |
||||
Refrigerant Injection in Coil | Indoor Unit |
6 Point - Multi Port |
||||
Dimension |
Indoor Unit |
mm |
280 x 750 x 635 |
280 x 950 x 635 |
280 x 1370 x 740 |
|
Outdoor Unit |
mm |
640 x 850 (+65) x 290 |
845 x 970 x 370 |
|||
Weight |
Indoor Unit |
Kgs |
29 |
34 |
54 |
54 |
Outdoor Unit |
Kgs |
40 |
47 |
64 |
75 |
|
Refrigerant | R410A |
|||||
Refrigerant Piping | Liquid/ Gas |
mm |
6.35 (1/4") / 15.88 (5/8") |
9.52 (3/8") / 15.88 (5/8") |
||
Maximum Piping Length | Mtrs |
30 mtrs / 100 feet |
50 mtrs 164 feet |
|||
Vertical Height difference | Mtrs |
Outdoor - Higher =10 mtrs / Lower = 10 mtrs |
Outdoor - Higher =30 mtrs / Lower = 15 mtrs |
|||
Main Power Supply to | Outdoor Unit |
2.5 mm2 x 3 cores (Including earthing) |
4 mm2 x 4 cores (Including earthing) |
|||
Connecting wiring | B/w IDU & ODU |
1.5 mm2 x 4 cores (Including earthing) |
||||
Area Coverage *** | Sq.Feet |
172 ~ 200 |
200 ~ 275 |
275 ~ 350 |
350 ~ 475 |
* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35 oC
** Under Standard Installation & Lab Test Condition
*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be air - conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice.