Model : FDT50CNV-S6, Ton : 1.5

Model : FDT50CNV-S6, Ton : 1.5

Model : FDT50CNV-S6, Ton : 1.5

  • Eco Smart Hybrid+CASSETTE
  • Refrigerant : R410A
  • Ton : 1.5
ECO SMART HYBRID+CASSETTE 4.0 Ton.
SPECIFICATIONS  
ECO SMART - CEILING CASSETTE - 4 WAY (R410A)
Unit  
FDT50CR-S
FDT71CR-S
FDT100CR-S
FDT125CR-S
Model
Indoor Unit
FDT50CR-S
FDT71CR-S
FDT100CR-S
FDT125CR-S
 
Outdoor Unit
FDC50CR-S
FDC71CR-S
FDC100CR-S
FDC125CR-S
Super Tropical - return Cooled Compressor
Rotary
Scroll
Type of AC
Heavy Duty AC
Hybrid AC
Power Source
1 Phase, 220 ~ 240 V, 50 Hz
3 Phase, 380 ~ 440 V, 50Hz

Maximum Cooling Capacity*
Ton
1.5
2.0
3.0
4.0
Watts
5363
7620
10550
14068
BTU/h
18300
26000
36000
48000
Maximum EER / COP*
W / w
3.57
3.54
3.51
3.51

Rated Cooling Capacity
Ton
1.5
2.0
3.0
4.0
Watts
5000
7108
10000
12500
BTU/h
17060
24255
34120
42650
Input Power** (Minimum ~ Maximum)
Watts
1300 ~ 1500
1900 ~ 2150
2700 ~ 3000
3700 ~ 4000
Rated EER / COP
W / w
3.33
3.30
3.33
3.12
Air Flow
Indoor Unit
CMH
1280
1680
2220
2500
Long reach AirFlow Upto
Indoor Unit
Feet
12
15
17
17
Sound level (H/M/l0
Indoor Unit
dB
36 / 30 / 28
38 / 32 / 30
45 / 37 / 34
46 / 40 / 37
Louver Swing
Indoor Unit
Yes (Individual Flap Control System Possible in Wired Controller)
Remote Control
Indoor Unit
Standard - Wired Controller include / Wireless Remote Controller Optional
Self Diagnosis Function
Indoor Unit
Yes
Filter
Indoor Unit
Anti - Bacterial
Fan
Indoor Unit
Supper Turbo Fan
DC Fan Motor Speed
Indoor Unit
Auto / High / Medium / Low / Dry
Refrigerant Injection in Coil
Indoor Unit
6 Point - Multi Port

Dimension
Indoor Unit
mm
280 x 750 x 635
280 x 950 x 635
280 x 1370 x 740
Outdoor Unit
mm

Unit : 246 x 840 x 840 , Panel : 35 x 950 x 950

Unit : 298 x 840 x 840 , Panel : 35 x 950 x 950


Weight
Indoor Unit
Kgs

27.5 Unit : 22 , Panel : 5.5

29.5 Unit : 24 , Panel : 5.5

32.5 Unit : 27 , Panel : 5.5

32.5 Unit : 27 , Panel : 5.5

Outdoor Unit
Kgs
40
47
64
75
Refrigerant
R410A
Refrigerant Piping
Liquid/ Gas
mm
6.35 (1/4") / 15.88 (5/8")
9.52 (3/8") / 15.88 (5/8")
Maximum Piping Length
Mtrs
30 mtrs / 100 feet
50 mtrs 164 feet
Vertical Height difference
Mtrs
Outdoor - Higher =10 mtrs / Lower = 10 mtrs
Outdoor - Higher =30 mtrs / Lower = 15 mtrs
Main Power Supply to
Outdoor Unit
2.5 mm2 x 3 cores (Including earthing)
4 mm2 x 4 cores (Including earthing)
Connecting wiring
B/w IDU & ODU
1.5 mm2 x 4 cores (Including earthing)
Area Coverage ***
Sq.Feet
172 ~ 200
200 ~ 275
275 ~ 350
350 ~ 475

* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35 oC
** Under Standard Installation & Lab Test Condition
*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be air - conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice.