Enquire Now

ECO SMART - HEAVY DUTY AC

Model : SRK 35 ZMX - S Ton :1.5

Hi- Wall Mounted, Heavy Duty
Eco Smart Heavy Duty AC
Refrigerant : R410A
Cooling Only
Model : SRK 35 ZMX - S
Ton : 1.5




Model : SRK 50 ZMX - S Ton :1.5

Hi- Wall Mounted, Heavy Duty
Eco Smart Heavy Duty AC
Refrigerant : R410A
Cooling Only
Model : SRK 50 ZMX - S
Ton : 1.5




Model : SRK 60 ZMX - S Ton : 1.5

Hi- Wall Mounted, Heavy Duty
Eco Smart Heavy Duty AC
Refrigerant : R410A
Cooling Only
Model : SRK 60 ZMX - S
Ton :1.5




Model : SRK 71 ZM - S Ton :1.5

ECO SMART HYBRIDE INVERTER(COOLING + HEATING)
SUPER HIGH EFFICIENCY EXCELLENT ENERGY SAVING
Presenting India's Highest Energy Saving
1.5 Ton Eco Smart Hyper Inverter AC With R 410 A
Refrigerant & With 4.40** EER.

ECO SMART HYBRID + gives 1.5 Times bigger area coverage compared to Conventional AC & still gives Electricity Saving Upto 47%*.

Description

ECO SMART HEAVY DUTY AIRCONDITIONER Presenting India's Highest Energy Saving 1.0 Ton Eco Smart Duty AC With R 410 A Refrigerant & Maximum 3.41* EER.

Features

Comfortable Air Flow Function        
                     
Clean Air Maintenance   Comfortable Function
                     
Other             Convenient & Economy Functions
                     

Techinical Specification

SPECIFICATIONS  
ECO SMART - HYPER INVERTER (R410A) - COOLING + HEATING
 
Unit
SRK35ZMX-S
SRK50ZMX-S
SRK60ZMX-s
SRK71ZM-S
MODEL
Indoor Unit
SRK35ZMX-S
SRK50ZMX-S
SRK60ZMX-s
SRK71ZM-S
 
Outdoor Unit
SRC35ZMX-S
SRC50ZMX-S
SRC60ZMX-S
SRC71ZM-S
Maximum Tonnage*
(Cooling/Heating)
1.25 / 1.45
1.76 / 2.1
2.0 / 2.3
2.3 / 2.8
Compressor Type
Super Tropical - Return Cooled - DC PAM Inverter - Twin Rotary
VFD - Variable frequency Drive
Inverter Vector Control Technology for Higher Efficiency
Minimum Compressor RPM
7 RPM - Using Vector Control Technology
LCD Remote Control (iPM Control)
iPM (Intelligent Power Module)
Power Source
1 Phase, 220 / 230 V, 50Hz
Maximum Capacity *(Cooling + Heating)
BTU/hr
15000 / 17400
21155 / 26272
23202 / 27978
27296 / 34120
Minimum Capacity (Cooling + Heating)
3000 / 3070
3000 / 3070
3500 / 3753
4265 / 4777
Rated Capacity (Cooling + Heating)
14000 / 14672
18015 / 20472
21155 / 23202
24225 / 27296
Maximum Capacity *(Cooling + Heating)
Watts
4396 / 5100
6200 / 7700
6800 / 8200
8000 / 10000
Minimum Capacity (Cooling + Heating)
880 / 900
880 / 900
1025 / 1100
1250/ 1500
Rated Capacity (Cooling + Heating)
4103 / 4300
5280 / 6000
6200 / 6800
7100 / 8000
Maximum Power Consumption **(Cooling + Heating)
Watts
1010 / 1350
1800 / 1900
2000 / 2300
2500 / 3000
Minimum Power Consumption ** (Cooling + Heating)
150 / 200
200 / 200
250 / 275
300 / 400
Rated Consumption **(Cooling + Heating)
800 / 900
1300 / 1360
1760 / 1840
2000 / 2000
EER / COP* at Maximum Cap.*(Cooling + Heating)
W/w
4.35 / 3.77
3.44 / 4.05
3.40 / 3.57
3.20 / 3.33
EER / COP* at Minimum Cap.(Cooling + Heating)
5.9 / 4.50
4.40 / 4.50
4.10 / 4.00
4.17 / 3.75
EER / COP** at Rated / Cap. **(Cooling + Heating)
5.12 / 4.77
4.06 / 4.41
3.52 / 3.70
3.55 / 3.64
Rated Current Cooling Mode(Minimum ~ Maximum)
A
0.65 ~ 4.0
0.87 ~ 6.0
1.0 ~ 8.0
1.30 ~ 9.80

Dimension (H x W x D)
Indoor Unit
mm
309 x 890 x 220
318 x 1098 x 248
Outdoor Unit
mm
595 x 780 (+62) x 290
640 x 800 (+71) x 290
750 x 880 (+88) x340

Weight
Indoor Unit
Kgs
13.5
15
15
17
Outdoor Unit
Kgs
35
45
45
59
Cooling Coil Row Indoor Unit
No.s
2
3
3
3
Air Flow (CMH) Indoor Unit
CMH
810
1100
1200
1500
Long Reach Air Flow Upto Indoor Unit
Feet
25
50
50
59
Self Diagnosis Function Indoor Unit
Yes
Yes
Yes
Yes
Sound Level (H/M/L/ULo) Indoor Unit
dB
43 / 33 / 25 / 22
45 / 38 / 27 / 25
47 / 40 / 29 / 25
47 / 47 / 37 / 26
Louver Swing Indoor Unit
3D + 3D AUTO
3D + 3D AUTO
3D + 3D AUTO
3D + 3D AUTO
Special Filter Indoor Unit
Allergen + Solor + Anti Bacterial - Filters
Blower Fan Indoor Unit
Anti - Micro Bial Fan
DC Fan Motor Speed Indoor Unit
Auto / Powerful / high / Medium / Low / ULo (Silent Mode)/ Dry
Refrigerant
R 410 A
R 410 A
R 410 A
R 410 A
Refrigerant Piping Thickness :19 Gauge(1mm) Liquid Line
mm
6.35 ( 1/4" )
GasLine
mm
9.52 ( 3/8" )
12.7 ( 1/2" )
12.7 ( 1/2" )
15.88( 5/8" )
Main Power Supply to Outdoor Unit
2.5 mm2 x 3 cores (With Earthing Cable)
Connecting Wiring B/w IDU & ODU
2.5 mm2 x 4 cores (With Earthing Cable)
Area Coverage ***  
Sq.Feet
130 ~ 185
170 ~ 225
225 ~ 300
300 ~ 500

* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35 oC
** Under Standard Installation & Lab Test Condition
*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be air - conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice