Enquire Now

Desert Xtreme Cooling (DXK) Hybrid+ Airconditioner

Model : DXK53CSS-S6 Ton : 1.6

Desert Xtreme
Cooling DXK
Refrigerant : R410A
Cooling Only
Model : DXK53CSS-S6
Ton : 1.6




Model : DXK74CSS-S6 Ton :2.2

Desert Xtreme
Cooling DXK
Refrigerant : R410A
Cooling Only
Model : DXK74CSS-S6
Ton : 2.2




Hybird AC gives 1.5 times bigger area coverage compared to Conventional AC & still gives electricity savings upto 47%.

Description

Features

Clean Air Maintenance   Comfortable Function
                     

Techinical Specification

SPECIFICATIONS    
ECO SMART - HAVY DUTY AC R ( R4410A )
 
Unit
DXK 37 CSS - S6
DXK 50 CS - S6
MODEL
Indoor Unit
DXK 37 CSS - S6
DXK 50 CS - S6
 
Outdoor Unit
DXC 37 CSS - S6
DXC 50 CS - S6
BEE Star Rating
5 STAR
3 STAR
Compressor Type
Super Topical - Returned Cooled Rotary
Power Source
1 Phase, 220 / 230 V, 50Hz
Maximum Cooling Capacity *
Ton
1.12
1.5
Watts
3957
5569
BTU/h
13500
19000
Maximum EER / COP *
W/w
3.96
3.41
BEE Rating Cooling Capacity
Ton
1.1
1.5
W
3600
5280
BTU/h
12283
18015
Input Power ** (Minimum ~ Maximum)
Watts
700 ~ 1000
1400 ~ 1615
BEE Rated EER / COP
W/w
3.60
3.27
Current (Minimum ~ Maximum) **
A
4.0 ~ 4.7
6.5 ~ 7.1
Dimension (H x W x D)
Indoor Unit
mm
368 x 790 x 213
309 x 890 x 251
Outdoor Unit
mm
595 x 780 x 290
640 x 850 ( + 65 ) x 290
 
Indoor Unit
kgs
9.5
14
Weight
Outdoor Unit
kgs
34
40
Indoor Unit
m3/hr 
750
1050
Air Flow ( CMH )
Indoor Unit
Feet
20
40
Long Reach Air Flow Upto
Indoor Unit
Yes
Self Diagnosis function
Indoor Unit
dB
38 / 34 / 31
45 / 43 / 41
Sound Level ( H/M/L )
Indoor Unit
3D + AUTO
2D
Louver Swing
Indoor Unit
Enzyme + Solor + Anti Bacterial Filter
Anti Bacterial
Special Filter
Indoor Unit
Anti - Micro Bial
Non Anti - Micro Bial
Blower Fan
Indoor Unit
AUTO / Power Ful / High / Med / Low
DC Fan Moter Speed
R410A
Refrigerant Injection in coil
Indoor Unit
4 Point - Multi Port
5 Point - Multi Port
Refrigerant Piping
Liquid Line
mm
6.35 ( 1/4" )
Gas Line
mm
12.7 ( 1/2" )
15.88 ( 5/8" )
Main Power Supply to
Outdoor Unit
2.5 mm2 x 3 core ( Including earthing cable )
Connecting Wiring
B/w IDU & ODU
1.5 mm2 x 3 core (earthing cable)
1.5 mm2 x 4 core (Including earthing cable)
Area coverage ***  
Sq.Feet
129 ~ 172
172 ~ 225

* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35 oC
** Under Standard Installation & Lab Test Condition
*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be air - conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice